Actual Torque Developed in Piston Pumps Formula

Fx Copy
LaTeX Copy
Actual Torque is the actual value of torque supplied to the pump. Check FAQs
Tactual=60Pin2πNd1
Tactual - Actual Torque?Pin - Input Power?Nd1 - Angular Speed of Driving Member in Piston Pump?π - Archimedes' constant?

Actual Torque Developed in Piston Pumps Example

With values
With units
Only example

Here is how the Actual Torque Developed in Piston Pumps equation looks like with Values.

Here is how the Actual Torque Developed in Piston Pumps equation looks like with Units.

Here is how the Actual Torque Developed in Piston Pumps equation looks like.

200.2688Edit=6045Edit23.141620.49Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Actual Torque Developed in Piston Pumps

Actual Torque Developed in Piston Pumps Solution

Follow our step by step solution on how to calculate Actual Torque Developed in Piston Pumps?

FIRST Step Consider the formula
Tactual=60Pin2πNd1
Next Step Substitute values of Variables
Tactual=6045W2π20.49rev/min
Next Step Substitute values of Constants
Tactual=6045W23.141620.49rev/min
Next Step Convert Units
Tactual=6045W23.14162.1457rad/s
Next Step Prepare to Evaluate
Tactual=604523.14162.1457
Next Step Evaluate
Tactual=200.268811016283N*m
LAST Step Rounding Answer
Tactual=200.2688N*m

Actual Torque Developed in Piston Pumps Formula Elements

Variables
Constants
Actual Torque
Actual Torque is the actual value of torque supplied to the pump.
Symbol: Tactual
Measurement: TorqueUnit: N*m
Note: Value can be positive or negative.
Input Power
Input Power is the power, which is required by the appliance at its input i.e., from the plug point.
Symbol: Pin
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Angular Speed of Driving Member in Piston Pump
The Angular Speed of Driving Member in Piston Pump is the rate of change of angular position of the driving or the input member.
Symbol: Nd1
Measurement: Angular VelocityUnit: rev/min
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Piston Pumps category

​Go Stroke Length of Axial Piston Pump
Ls=dbtan(θ)
​Go Theoretical Volumetric Displacement given Area of Piston and Stroke Length
Vp=nApLs
​Go Theoretical Volumetric Displacement given Bore Diameter and Swash Plate Inclination
Vp=nApdbtan(θ)
​Go Piston Pump Constant K
K=πndp2db4

How to Evaluate Actual Torque Developed in Piston Pumps?

Actual Torque Developed in Piston Pumps evaluator uses Actual Torque = (60*Input Power)/(2*pi*Angular Speed of Driving Member in Piston Pump) to evaluate the Actual Torque, Actual Torque Developed in Piston Pumps formula is defined as the measure of the rotational force that drives the movement of fluids in a hydraulic pump, which is influenced by the inlet pressure and the design characteristics of the pump. Actual Torque is denoted by Tactual symbol.

How to evaluate Actual Torque Developed in Piston Pumps using this online evaluator? To use this online evaluator for Actual Torque Developed in Piston Pumps, enter Input Power (Pin) & Angular Speed of Driving Member in Piston Pump (Nd1) and hit the calculate button.

FAQs on Actual Torque Developed in Piston Pumps

What is the formula to find Actual Torque Developed in Piston Pumps?
The formula of Actual Torque Developed in Piston Pumps is expressed as Actual Torque = (60*Input Power)/(2*pi*Angular Speed of Driving Member in Piston Pump). Here is an example- 293.1077 = (60*45)/(2*pi*2.14570778229256).
How to calculate Actual Torque Developed in Piston Pumps?
With Input Power (Pin) & Angular Speed of Driving Member in Piston Pump (Nd1) we can find Actual Torque Developed in Piston Pumps using the formula - Actual Torque = (60*Input Power)/(2*pi*Angular Speed of Driving Member in Piston Pump). This formula also uses Archimedes' constant .
Can the Actual Torque Developed in Piston Pumps be negative?
Yes, the Actual Torque Developed in Piston Pumps, measured in Torque can be negative.
Which unit is used to measure Actual Torque Developed in Piston Pumps?
Actual Torque Developed in Piston Pumps is usually measured using the Newton Meter[N*m] for Torque. Newton Centimeter[N*m], Newton Millimeter[N*m], Kilonewton Meter[N*m] are the few other units in which Actual Torque Developed in Piston Pumps can be measured.
Copied!