Fx Copy
LaTeX Copy
Temperature given PRP is the degree or intensity of heat present in a substance or object. Check FAQs
TPRP=Tr(bPRPc0.07780[R])
TPRP - Temperature given PRP?Tr - Reduced Temperature?bPR - Peng–Robinson Parameter b?Pc - Critical Pressure?[R] - Universal gas constant?

Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters Example

With values
With units
Only example

Here is how the Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters equation looks like with Values.

Here is how the Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters equation looks like with Units.

Here is how the Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters equation looks like.

404.4119Edit=10Edit(0.12Edit218Edit0.077808.3145)
You are here -

Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters Solution

Follow our step by step solution on how to calculate Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters?

FIRST Step Consider the formula
TPRP=Tr(bPRPc0.07780[R])
Next Step Substitute values of Variables
TPRP=10(0.12218Pa0.07780[R])
Next Step Substitute values of Constants
TPRP=10(0.12218Pa0.077808.3145)
Next Step Prepare to Evaluate
TPRP=10(0.122180.077808.3145)
Next Step Evaluate
TPRP=404.411929038267K
LAST Step Rounding Answer
TPRP=404.4119K

Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters Formula Elements

Variables
Constants
Temperature given PRP
Temperature given PRP is the degree or intensity of heat present in a substance or object.
Symbol: TPRP
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Reduced Temperature
Reduced Temperature is the ratio of the actual temperature of the fluid to its critical temperature. It is dimensionless.
Symbol: Tr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peng–Robinson Parameter b
Peng–Robinson parameter b is an empirical parameter characteristic to equation obtained from Peng–Robinson model of real gas.
Symbol: bPR
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Critical Pressure
Critical Pressure is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: Pc
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Universal gas constant
Universal gas constant is a fundamental physical constant that appears in the ideal gas law, relating the pressure, volume, and temperature of an ideal gas.
Symbol: [R]
Value: 8.31446261815324

Other Formulas to find Temperature given PRP

​Go Reduced Temperature using Redlich Kwong Equation given of 'a' and 'b'
TPRP=Tg(323)(((213)-1)43)((ab[R])23)

Other formulas in Peng Robinson Model of Real Gas category

​Go Actual Pressure given Peng Robinson Parameter a, and other Reduced and Critical Parameters
PPRP=Pr(0.45724([R]2)Tc2aPR)
​Go Temperature of Real Gas using Peng Robinson Equation
TCE=(p+((aPRα(Vm2)+(2bPRVm)-(bPR2))))(Vm-bPR[R])
​Go Critical Pressure given Peng Robinson Parameter b and other Actual and Reduced Parameters
PcPRP=0.07780[R]TgTrbPR
​Go Critical Temperature using Peng Robinson Equation given Reduced and Actual Parameters
Treal=(p+((aPRα(Vm2)+(2bPRVm)-(bPR2))))(Vm-bPR[R])Tr

How to Evaluate Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters?

Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters evaluator uses Temperature given PRP = Reduced Temperature*((Peng–Robinson Parameter b*Critical Pressure)/(0.07780*[R])) to evaluate the Temperature given PRP, The Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters formula is defined as the degree or intensity of heat present in the volume of real gas. Temperature given PRP is denoted by TPRP symbol.

How to evaluate Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters using this online evaluator? To use this online evaluator for Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters, enter Reduced Temperature (Tr), Peng–Robinson Parameter b (bPR) & Critical Pressure (Pc) and hit the calculate button.

FAQs on Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters

What is the formula to find Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters?
The formula of Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters is expressed as Temperature given PRP = Reduced Temperature*((Peng–Robinson Parameter b*Critical Pressure)/(0.07780*[R])). Here is an example- 404.4119 = 10*((0.12*218)/(0.07780*[R])).
How to calculate Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters?
With Reduced Temperature (Tr), Peng–Robinson Parameter b (bPR) & Critical Pressure (Pc) we can find Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters using the formula - Temperature given PRP = Reduced Temperature*((Peng–Robinson Parameter b*Critical Pressure)/(0.07780*[R])). This formula also uses Universal gas constant .
What are the other ways to Calculate Temperature given PRP?
Here are the different ways to Calculate Temperature given PRP-
  • Temperature given PRP=Temperature of Gas/((3^(2/3))*(((2^(1/3))-1)^(4/3))*((Redlich–Kwong Parameter a/(Redlich–Kwong parameter b*[R]))^(2/3)))OpenImg
Can the Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters be negative?
Yes, the Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters, measured in Temperature can be negative.
Which unit is used to measure Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters?
Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Actual Temperature given Peng Robinson parameter b, other reduced and critical parameters can be measured.
Copied!