Actual Power Transmitted given Power Transmitted by Flat for Design Purpose Formula

Fx Copy
LaTeX Copy
Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley. Check FAQs
Pt=PdFa
Pt - Power transmitted by belt?Pd - Design Power of Belt Drive?Fa - Load Correction Factor?

Actual Power Transmitted given Power Transmitted by Flat for Design Purpose Example

With values
With units
Only example

Here is how the Actual Power Transmitted given Power Transmitted by Flat for Design Purpose equation looks like with Values.

Here is how the Actual Power Transmitted given Power Transmitted by Flat for Design Purpose equation looks like with Units.

Here is how the Actual Power Transmitted given Power Transmitted by Flat for Design Purpose equation looks like.

6.4435Edit=7.41Edit1.15Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Machine Design » fx Actual Power Transmitted given Power Transmitted by Flat for Design Purpose

Actual Power Transmitted given Power Transmitted by Flat for Design Purpose Solution

Follow our step by step solution on how to calculate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?

FIRST Step Consider the formula
Pt=PdFa
Next Step Substitute values of Variables
Pt=7.41kW1.15
Next Step Convert Units
Pt=7410W1.15
Next Step Prepare to Evaluate
Pt=74101.15
Next Step Evaluate
Pt=6443.47826086957W
Next Step Convert to Output's Unit
Pt=6.44347826086957kW
LAST Step Rounding Answer
Pt=6.4435kW

Actual Power Transmitted given Power Transmitted by Flat for Design Purpose Formula Elements

Variables
Power transmitted by belt
Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
Symbol: Pt
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Design Power of Belt Drive
Design Power of Belt Drive is defined as the power transmitted on the basis of the design.
Symbol: Pd
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Load Correction Factor
Load Correction Factor increases the power factor of a load, improving efficiency for the distribution system to which it is attached.
Symbol: Fa
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Maximum Power Conditions category

​Go Initial Tension in Belt Drive
Pi=P1+P22
​Go Belt Tension in Tight Side of Belt given Initial Tension in Belt
P1=2Pi-P2
​Go Belt Tension in Loose Side of Belt given Initial Tension in Belt
P2=2Pi-P1
​Go Optimum Velocity of Belt for Maximum Power Transmission
vo=Pi3m

How to Evaluate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?

Actual Power Transmitted given Power Transmitted by Flat for Design Purpose evaluator uses Power transmitted by belt = Design Power of Belt Drive/Load Correction Factor to evaluate the Power transmitted by belt, The Actual Power Transmitted given Power Transmitted by Flat for Design Purpose formula is defined as the actual power transmitted by the flat belts after all losses in given power applications. Power transmitted by belt is denoted by Pt symbol.

How to evaluate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose using this online evaluator? To use this online evaluator for Actual Power Transmitted given Power Transmitted by Flat for Design Purpose, enter Design Power of Belt Drive (Pd) & Load Correction Factor (Fa) and hit the calculate button.

FAQs on Actual Power Transmitted given Power Transmitted by Flat for Design Purpose

What is the formula to find Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?
The formula of Actual Power Transmitted given Power Transmitted by Flat for Design Purpose is expressed as Power transmitted by belt = Design Power of Belt Drive/Load Correction Factor. Here is an example- 0.006443 = 7410/1.15.
How to calculate Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?
With Design Power of Belt Drive (Pd) & Load Correction Factor (Fa) we can find Actual Power Transmitted given Power Transmitted by Flat for Design Purpose using the formula - Power transmitted by belt = Design Power of Belt Drive/Load Correction Factor.
Can the Actual Power Transmitted given Power Transmitted by Flat for Design Purpose be negative?
No, the Actual Power Transmitted given Power Transmitted by Flat for Design Purpose, measured in Power cannot be negative.
Which unit is used to measure Actual Power Transmitted given Power Transmitted by Flat for Design Purpose?
Actual Power Transmitted given Power Transmitted by Flat for Design Purpose is usually measured using the Kilowatt[kW] for Power. Watt[kW], Milliwatt[kW], Microwatt[kW] are the few other units in which Actual Power Transmitted given Power Transmitted by Flat for Design Purpose can be measured.