Active Power in DC Circuit is defined as the actual work done or energy transferred by the circuit. Check FAQs
Pdc=3VlineIlinecos(θph)
Pdc - Active Power in DC Circuit?Vline - Line Voltage?Iline - Line Current?θph - Phase Angle?

Active Power in Three Phase (L-L) AC Circuits Example

With values
With units
Only example

Here is how the Active Power in Three Phase (L-L) AC Circuits equation looks like with Values.

Here is how the Active Power in Three Phase (L-L) AC Circuits equation looks like with Units.

Here is how the Active Power in Three Phase (L-L) AC Circuits equation looks like.

168Edit=356Edit2Editcos(30Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Active Power in Three Phase (L-L) AC Circuits

Active Power in Three Phase (L-L) AC Circuits Solution

Follow our step by step solution on how to calculate Active Power in Three Phase (L-L) AC Circuits?

FIRST Step Consider the formula
Pdc=3VlineIlinecos(θph)
Next Step Substitute values of Variables
Pdc=356V2Acos(30°)
Next Step Convert Units
Pdc=356V2Acos(0.5236rad)
Next Step Prepare to Evaluate
Pdc=3562cos(0.5236)
LAST Step Evaluate
Pdc=168W

Active Power in Three Phase (L-L) AC Circuits Formula Elements

Variables
Functions
Active Power in DC Circuit
Active Power in DC Circuit is defined as the actual work done or energy transferred by the circuit.
Symbol: Pdc
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Line Voltage
Line Voltage refers to the potential difference between two conductors in a polyphase system, most commonly a three-phase system.
Symbol: Vline
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Line Current
Line Current, similar to line voltage, refers to the current flowing in each individual conductor of a polyphase system, typically a three-phase system.
Symbol: Iline
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Phase Angle
Phase Angle characteristic of a periodic wave. The angular component periodic wave is known as the phase angle. It is a complex quantity measured by angular units like radians or degrees.
Symbol: θph
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Active Power in DC Circuit

​Go Active Power in Single Phase AC Circuits
Pdc=VapIcorrcos(θph)

Other formulas in Power Factor Correction category

​Go Compensated Reactive Power for Mechanical Loads Power Factor
Q2=Pmax(tan(φ1)-tan(φ2))
​Go Maximum Power for Iron Loss in Power Factor Correction
Pmax=0.02Stfr
​Go Copper Loss of Power Factor Correction
Culoss=(Zv100)Stfr
​Go Actual Power Factor Correction
PF=cos(tanh(tan(PFinitial)-Icorr))

How to Evaluate Active Power in Three Phase (L-L) AC Circuits?

Active Power in Three Phase (L-L) AC Circuits evaluator uses Active Power in DC Circuit = sqrt(3)*Line Voltage*Line Current*cos(Phase Angle) to evaluate the Active Power in DC Circuit, Active Power in Three Phase (L-L) AC Circuits, naturally known as line to line real power generally refers to the actual rate of electrical work being done by the source on the load. This is the usable power that delivers a practical effect like generating heat, light, or mechanical work. The formula above applies to balanced three-phase systems where the voltages and currents on each phase are equal and have the same phase angle. In unbalanced systems, the calculation becomes more complex and requires individual phase voltage and current measurements. Active Power in DC Circuit is denoted by Pdc symbol.

How to evaluate Active Power in Three Phase (L-L) AC Circuits using this online evaluator? To use this online evaluator for Active Power in Three Phase (L-L) AC Circuits, enter Line Voltage (Vline), Line Current (Iline) & Phase Angle ph) and hit the calculate button.

FAQs on Active Power in Three Phase (L-L) AC Circuits

What is the formula to find Active Power in Three Phase (L-L) AC Circuits?
The formula of Active Power in Three Phase (L-L) AC Circuits is expressed as Active Power in DC Circuit = sqrt(3)*Line Voltage*Line Current*cos(Phase Angle). Here is an example- 45.69 = sqrt(3)*56*2*cos(0.5235987755982).
How to calculate Active Power in Three Phase (L-L) AC Circuits?
With Line Voltage (Vline), Line Current (Iline) & Phase Angle ph) we can find Active Power in Three Phase (L-L) AC Circuits using the formula - Active Power in DC Circuit = sqrt(3)*Line Voltage*Line Current*cos(Phase Angle). This formula also uses Cosine (cos), Square Root (sqrt) function(s).
What are the other ways to Calculate Active Power in DC Circuit?
Here are the different ways to Calculate Active Power in DC Circuit-
  • Active Power in DC Circuit=Voltage*Corrected Current in AC Circuit*cos(Phase Angle)OpenImg
Can the Active Power in Three Phase (L-L) AC Circuits be negative?
No, the Active Power in Three Phase (L-L) AC Circuits, measured in Power cannot be negative.
Which unit is used to measure Active Power in Three Phase (L-L) AC Circuits?
Active Power in Three Phase (L-L) AC Circuits is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Active Power in Three Phase (L-L) AC Circuits can be measured.
Copied!