Fx Copy
LaTeX Copy
Active Area is the area made available for the vapor component to travel in a Tray tower where liquid-vapor contacting takes place. Check FAQs
Aa=Gvfduf
Aa - Active Area?Gv - Volumetric Gas Flow?fd - Fractional Downcomer Area?uf - Flooding Velocity?

Active Area given Gas Volumetric Flow and Flow Velocity Example

With values
With units
Only example

Here is how the Active Area given Gas Volumetric Flow and Flow Velocity equation looks like with Values.

Here is how the Active Area given Gas Volumetric Flow and Flow Velocity equation looks like with Units.

Here is how the Active Area given Gas Volumetric Flow and Flow Velocity equation looks like.

3.8782Edit=0.9873Edit0.12Edit2.1215Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Active Area given Gas Volumetric Flow and Flow Velocity

Active Area given Gas Volumetric Flow and Flow Velocity Solution

Follow our step by step solution on how to calculate Active Area given Gas Volumetric Flow and Flow Velocity?

FIRST Step Consider the formula
Aa=Gvfduf
Next Step Substitute values of Variables
Aa=0.9873m³/s0.122.1215m/s
Next Step Prepare to Evaluate
Aa=0.98730.122.1215
Next Step Evaluate
Aa=3.87823473957106
LAST Step Rounding Answer
Aa=3.8782

Active Area given Gas Volumetric Flow and Flow Velocity Formula Elements

Variables
Active Area
Active Area is the area made available for the vapor component to travel in a Tray tower where liquid-vapor contacting takes place.
Symbol: Aa
Measurement: AreaUnit:
Note: Value should be greater than 0.
Volumetric Gas Flow
Volumetric Gas Flow is the volumetric flowrate of the vapor/gas phase that travels across the Column undergoing unit process and operations.
Symbol: Gv
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Fractional Downcomer Area
Fractional Downcomer Area refers to the ratio of tower cross sectional area occupied by the downcomers on both side of column.
Symbol: fd
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Flooding Velocity
Flooding velocity refers to the maximum vapor velocity that exceeds a certain critical value which would result into flooding in a tray tower.
Symbol: uf
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Active Area

​Go Active Area Given Total Area and Fractional Downcomer Area
Aa=AT(1-fd)

Other formulas in Distillation Tower Design category

​Go Clearance Area under Downcomer given Weir Length and Apron Height
Aap=haplw
​Go Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
Dc=(4VWπWmax)12
​Go Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
Dc=4VWπρVUv
​Go Downcomer Residence Time in Distillation Column
tr=AdhbcρLLw

How to Evaluate Active Area given Gas Volumetric Flow and Flow Velocity?

Active Area given Gas Volumetric Flow and Flow Velocity evaluator uses Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity) to evaluate the Active Area, The Active Area given Gas Volumetric Flow and Flow Velocity formula is defined as the area available for the vapor phase to travel in a column for a known value of volumetric flowrate of vapor/gas phase. Active Area is denoted by Aa symbol.

How to evaluate Active Area given Gas Volumetric Flow and Flow Velocity using this online evaluator? To use this online evaluator for Active Area given Gas Volumetric Flow and Flow Velocity, enter Volumetric Gas Flow (Gv), Fractional Downcomer Area (fd) & Flooding Velocity (uf) and hit the calculate button.

FAQs on Active Area given Gas Volumetric Flow and Flow Velocity

What is the formula to find Active Area given Gas Volumetric Flow and Flow Velocity?
The formula of Active Area given Gas Volumetric Flow and Flow Velocity is expressed as Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity). Here is an example- 3.878235 = 0.987321/(0.12*2.1215).
How to calculate Active Area given Gas Volumetric Flow and Flow Velocity?
With Volumetric Gas Flow (Gv), Fractional Downcomer Area (fd) & Flooding Velocity (uf) we can find Active Area given Gas Volumetric Flow and Flow Velocity using the formula - Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity).
What are the other ways to Calculate Active Area?
Here are the different ways to Calculate Active Area-
  • Active Area=Tower Cross Sectional Area*(1-Fractional Downcomer Area)OpenImg
Can the Active Area given Gas Volumetric Flow and Flow Velocity be negative?
No, the Active Area given Gas Volumetric Flow and Flow Velocity, measured in Area cannot be negative.
Which unit is used to measure Active Area given Gas Volumetric Flow and Flow Velocity?
Active Area given Gas Volumetric Flow and Flow Velocity is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Active Area given Gas Volumetric Flow and Flow Velocity can be measured.
Copied!