Fx Copy
LaTeX Copy
Acentric Factor is a standard for the phase characterization of single & pure components. Check FAQs
ω=-1-ln(Prsat)
ω - Acentric Factor?Prsat - Saturated Reduced Pressure at Reduced Temp 0.7?

Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 Example

With values
With units
Only example

Here is how the Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 equation looks like with Values.

Here is how the Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 equation looks like with Units.

Here is how the Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 equation looks like.

9.2127Edit=-1-ln(3.7E-5Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Thermodynamics » fx Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7

Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 Solution

Follow our step by step solution on how to calculate Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7?

FIRST Step Consider the formula
ω=-1-ln(Prsat)
Next Step Substitute values of Variables
ω=-1-ln(3.7E-5)
Next Step Prepare to Evaluate
ω=-1-ln(3.7E-5)
Next Step Evaluate
ω=9.21273380290375
LAST Step Rounding Answer
ω=9.2127

Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 Formula Elements

Variables
Functions
Acentric Factor
Acentric Factor is a standard for the phase characterization of single & pure components.
Symbol: ω
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Saturated Reduced Pressure at Reduced Temp 0.7
Saturated Reduced Pressure at Reduced Temp 0.7 is the ratio of the actual pressure of the fluid to its critical pressure at a reduced temperature of 0.7. It is a dimensionless parameter.
Symbol: Prsat
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other Formulas to find Acentric Factor

​Go Acentric Factor using Pitzer Correlations for Compressibility Factor
ω=z-Z0Z1
​Go Acentric Factor using B(0) and B(1) of Pitzer Correlations for Second Virial Coefficient
ω=B^-B0B1

Other formulas in Equation of States category

​Go Reduced Pressure
Pr=pPc
​Go Reduced Temperature
Tr=TTc
​Go Compressibility Factor using Pitzer Correlations for Compressibility Factor
z=Z0+ωZ1
​Go Compressibility Factor using Second Virial Coefficient
z=1+(Bp[R]T)

How to Evaluate Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7?

Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 evaluator uses Acentric Factor = -1-ln(Saturated Reduced Pressure at Reduced Temp 0.7) to evaluate the Acentric Factor, The Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 formula is defined as the difference between the natural logarithm of the saturated reduced pressure of the simple fluid (which is -1) and pure fluid. Acentric Factor is denoted by ω symbol.

How to evaluate Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 using this online evaluator? To use this online evaluator for Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7, enter Saturated Reduced Pressure at Reduced Temp 0.7 (Prsat) and hit the calculate button.

FAQs on Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7

What is the formula to find Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7?
The formula of Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 is expressed as Acentric Factor = -1-ln(Saturated Reduced Pressure at Reduced Temp 0.7). Here is an example- 9.212734 = -1-ln(3.67E-05).
How to calculate Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7?
With Saturated Reduced Pressure at Reduced Temp 0.7 (Prsat) we can find Acentric Factor using Saturated Reduced Pressure given at Reduced Temperature 0.7 using the formula - Acentric Factor = -1-ln(Saturated Reduced Pressure at Reduced Temp 0.7). This formula also uses Natural Logarithm (ln) function(s).
What are the other ways to Calculate Acentric Factor?
Here are the different ways to Calculate Acentric Factor-
  • Acentric Factor=(Compressibility Factor-Pitzer Correlations Coefficient Z(0))/Pitzer Correlations Coefficient Z(1)OpenImg
  • Acentric Factor=(Reduced Second Virial Coefficient-Pitzer Correlations Coefficient B(0))/Pitzer Correlations Coefficient B(1)OpenImg
Copied!