Absorbed Power Formula

Fx Copy
LaTeX Copy
Absorbed Power is defined as the power consumed by a solid state device while operating. Check FAQs
Pabs=Piexp(-bα)
Pabs - Absorbed Power?Pi - Incident Power?b - Sample Thickness?α - Absorption Coefficient?

Absorbed Power Example

With values
With units
Only example

Here is how the Absorbed Power equation looks like with Values.

Here is how the Absorbed Power equation looks like with Units.

Here is how the Absorbed Power equation looks like.

0.1073Edit=0.22Editexp(-0.46Edit15608.42Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Solid State Devices » fx Absorbed Power

Absorbed Power Solution

Follow our step by step solution on how to calculate Absorbed Power?

FIRST Step Consider the formula
Pabs=Piexp(-bα)
Next Step Substitute values of Variables
Pabs=0.22Wexp(-0.46μm15608.42cm⁻¹)
Next Step Convert Units
Pabs=0.22Wexp(-4.6E-7m1.6E+6m⁻¹)
Next Step Prepare to Evaluate
Pabs=0.22exp(-4.6E-71.6E+6)
Next Step Evaluate
Pabs=0.107301242188786W
LAST Step Rounding Answer
Pabs=0.1073W

Absorbed Power Formula Elements

Variables
Functions
Absorbed Power
Absorbed Power is defined as the power consumed by a solid state device while operating.
Symbol: Pabs
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Incident Power
Incident Power is the intensity of the incident light ray striking the surface.
Symbol: Pi
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Sample Thickness
Sample Thickness is defined as the total distance between the two planes of the sample taken.
Symbol: b
Measurement: LengthUnit: μm
Note: Value should be greater than 0.
Absorption Coefficient
Absorption Coefficient determines how far into a material, light of a particular wavelength can penetrate before it is absorbed.
Symbol: α
Measurement: Reciprocal LengthUnit: cm⁻¹
Note: Value should be greater than 0.
exp
n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable.
Syntax: exp(Number)

Other formulas in SSD Junction category

​Go N-Type Width
xno=|Q|AjNa[Charge-e]
​Go Junction Capacitance
Cj=(Aj2)2[Charge-e]kNBV-V1
​Go Junction Voltage
Vj=V-(Rse(p)+Rse(n))I
​Go Series Resistance in P-type
Rse(p)=(V-VjI)-Rse(n)

How to Evaluate Absorbed Power?

Absorbed Power evaluator uses Absorbed Power = Incident Power*exp(-Sample Thickness*Absorption Coefficient) to evaluate the Absorbed Power, The Absorbed Power formula is defined as the intensity of light transmitted through the sample thickness. Absorbed Power is denoted by Pabs symbol.

How to evaluate Absorbed Power using this online evaluator? To use this online evaluator for Absorbed Power, enter Incident Power (Pi), Sample Thickness (b) & Absorption Coefficient (α) and hit the calculate button.

FAQs on Absorbed Power

What is the formula to find Absorbed Power?
The formula of Absorbed Power is expressed as Absorbed Power = Incident Power*exp(-Sample Thickness*Absorption Coefficient). Here is an example- 0.107301 = 0.22*exp(-4.6E-07*1560842).
How to calculate Absorbed Power?
With Incident Power (Pi), Sample Thickness (b) & Absorption Coefficient (α) we can find Absorbed Power using the formula - Absorbed Power = Incident Power*exp(-Sample Thickness*Absorption Coefficient). This formula also uses Exponential Growth Function function(s).
Can the Absorbed Power be negative?
Yes, the Absorbed Power, measured in Power can be negative.
Which unit is used to measure Absorbed Power?
Absorbed Power is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Absorbed Power can be measured.
Copied!