Bm=12πts
Bm - Maximum 3db Bandwidth?ts - Transit Time?π - Archimedes' constant?

3 dB Bandwidth of Metal Photodetectors Example

With values
With units
Only example

Here is how the 3 dB Bandwidth of Metal Photodetectors equation looks like with Values.

Here is how the 3 dB Bandwidth of Metal Photodetectors equation looks like with Units.

Here is how the 3 dB Bandwidth of Metal Photodetectors equation looks like.

0.0133Edit=123.141612.01Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Fiber Optic Transmission » fx 3 dB Bandwidth of Metal Photodetectors

3 dB Bandwidth of Metal Photodetectors Solution

Follow our step by step solution on how to calculate 3 dB Bandwidth of Metal Photodetectors?

FIRST Step Consider the formula
Bm=12πts
Next Step Substitute values of Variables
Bm=12π12.01s
Next Step Substitute values of Constants
Bm=123.141612.01s
Next Step Prepare to Evaluate
Bm=123.141612.01
Next Step Evaluate
Bm=0.0132518687004076Hz
LAST Step Rounding Answer
Bm=0.0133Hz

3 dB Bandwidth of Metal Photodetectors Formula Elements

Variables
Constants
Maximum 3db Bandwidth
Maximum 3dB Bandwidth of the photodiode is the frequency at which the photodiode's response drops to -3 decibels (dB) or approximately 70.7% of its maximum response.
Symbol: Bm
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.
Transit Time
Transit time is the duration for a charge carrier to move from where it's created in the photodetector's semiconductor material to where it's collected by the electrodes.
Symbol: ts
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other Formulas to find Maximum 3db Bandwidth

​Go Maximum Photodiode 3 dB Bandwidth
Bm=υd2πw
​Go Maximum 3dB Bandwidth of Metal Photodetector
Bm=12πtsG

Other formulas in Optical Detectors category

​Go Quantum Efficiency of Photodetector
η=NeNp
​Go Incident Photon Rate
Ri=Pi[hP]Fi
​Go Electron Rate in Detector
Rp=ηRi
​Go Long Wavelength Cutoff Point
λc=[hP][c]Eg

How to Evaluate 3 dB Bandwidth of Metal Photodetectors?

3 dB Bandwidth of Metal Photodetectors evaluator uses Maximum 3db Bandwidth = 1/(2*pi*Transit Time) to evaluate the Maximum 3db Bandwidth, 3 dB Bandwidth of Metal Photodetectors is the common metric used to describe the frequency response or the gain response of the photodetector. In other words, it's the frequency range over which the photodetector can accurately detect and respond to changes in light intensity. Maximum 3db Bandwidth is denoted by Bm symbol.

How to evaluate 3 dB Bandwidth of Metal Photodetectors using this online evaluator? To use this online evaluator for 3 dB Bandwidth of Metal Photodetectors, enter Transit Time (ts) and hit the calculate button.

FAQs on 3 dB Bandwidth of Metal Photodetectors

What is the formula to find 3 dB Bandwidth of Metal Photodetectors?
The formula of 3 dB Bandwidth of Metal Photodetectors is expressed as Maximum 3db Bandwidth = 1/(2*pi*Transit Time). Here is an example- 0.013263 = 1/(2*pi*12.01).
How to calculate 3 dB Bandwidth of Metal Photodetectors?
With Transit Time (ts) we can find 3 dB Bandwidth of Metal Photodetectors using the formula - Maximum 3db Bandwidth = 1/(2*pi*Transit Time). This formula also uses Archimedes' constant .
What are the other ways to Calculate Maximum 3db Bandwidth?
Here are the different ways to Calculate Maximum 3db Bandwidth-
  • Maximum 3db Bandwidth=Carrier Velocity/(2*pi*Depletion Layer Width)OpenImg
  • Maximum 3db Bandwidth=1/(2*pi*Transit Time*PhotoConductive Gain)OpenImg
Can the 3 dB Bandwidth of Metal Photodetectors be negative?
No, the 3 dB Bandwidth of Metal Photodetectors, measured in Frequency cannot be negative.
Which unit is used to measure 3 dB Bandwidth of Metal Photodetectors?
3 dB Bandwidth of Metal Photodetectors is usually measured using the Hertz[Hz] for Frequency. Petahertz[Hz], Terahertz[Hz], Gigahertz[Hz] are the few other units in which 3 dB Bandwidth of Metal Photodetectors can be measured.
Copied!