Zero Sequence Impedance LG in L G Fault Formulas
Zero Sequence Impedance LG consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counter clockwise together. And is denoted by Z
0(lg)
. Zero Sequence Impedance LG is usually measured using the Ohm for Electric Resistance. Note that the value of Zero Sequence Impedance LG is always negative.
Formulas to find Zero Sequence Impedance LG in L G Fault
f
x
Zero Sequence Impedance for L-G-F
Go
f
x
Zero Sequence Impedance using A-Phase EMF (LGF)
Go
L G Fault formulas that make use of Zero Sequence Impedance LG
f
x
Zero Sequence Current for L-G-F
Go
f
x
Zero Sequence Current using A-Phase EMF (LGF)
Go
f
x
Positive Sequence Current using A-Phase EMF (LGF)
Go
f
x
Negative Sequence Current using A-Phase EMF (LGF)
Go
f
x
A-Phase Current using A-Phase EMF(LGF)
Go
f
x
A-Phase Current using Fault Voltage and Fault Impedance(LGF)
Go
f
x
Zero Sequence Voltage for LGF
Go
f
x
A-Phase EMF using Zero Sequence Current (LGF)
Go
f
x
A-Phase EMF using Positive Sequence Current(LGF)
Go
f
x
A-Phase EMF using Negative Sequence Current (LGF)
Go
f
x
Positive Sequence Voltage using A-Phase EMF and Sequence Impedances(LGF)
Go
f
x
Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LGF)
Go
f
x
Positive Sequence Impedance using A-Phase EMF (LGF)
Go
f
x
Fault Impedance given A-Phase EMF and Sequence Impedances(LGF)
Go
f
x
Fault Impedance using Fault Voltage and A-Phase Current(LGF)
Go
f
x
Negative Sequence Impedance using A-Phase EMF (LGF)
Go
List of variables in L G Fault formulas
f
x
Zero Sequence Voltage LG
Go
f
x
Zero Sequence Current LG
Go
f
x
EMF Induced in Primary Winding LG
Go
f
x
Fault Impedance LG
Go
f
x
Positive Sequence Impedance LG
Go
f
x
Negative Sequence Impedance LG
Go
FAQ
What is the Zero Sequence Impedance LG?
Zero Sequence Impedance LG consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counter clockwise together. Zero Sequence Impedance LG is usually measured using the Ohm for Electric Resistance. Note that the value of Zero Sequence Impedance LG is always negative.
Can the Zero Sequence Impedance LG be negative?
Yes, the Zero Sequence Impedance LG, measured in Electric Resistance can be negative.
What unit is used to measure Zero Sequence Impedance LG?
Zero Sequence Impedance LG is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Zero Sequence Impedance LG can be measured.