FormulaDen.com
Physics
Chemistry
Math
Chemical Engineering
Civil
Electrical
Electronics
Electronics and Instrumentation
Materials Science
Mechanical
Production Engineering
Financial
Health
You are here
-
Home
»
Engineering
»
Electrical
»
Power System
Power Transmitted in 2 Φ 3 Wire System Formulas
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work. And is denoted by P. Power Transmitted is usually measured using the Watt for Power. Note that the value of Power Transmitted is always negative.
Formulas to find Power Transmitted in 2 Φ 3 Wire System
f
x
Power Transmitted using Volume of Conductor Material (2 Phase 3 Wire US)
Go
f
x
Transmitted Power using Line Losses (2-Phase 3-Wire US)
Go
f
x
Power Transmitted using Current in Each Outer (2-Phase 3-Wire US)
Go
f
x
Power Transmitted using Current in Neutral Wire (2-Phase 3-Wire US)
Go
2 Φ 3 Wire System formulas that make use of Power Transmitted
f
x
Resistivity using Volume of Conductor Material (2 Phase 3 Wire US)
Go
f
x
Resistivity using Line Losses (2-Phase 3-Wire US)
Go
f
x
Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Go
f
x
Length using Volume of Conductor Material (2 Phase 3 Wire US)
Go
f
x
Area of X-Section using Line Losses (2-Phase 3-Wire US)
Go
f
x
Angle of Pf using Line Losses (2-Phase 3-Wire US)
Go
f
x
Length using Line Losses (2-Phase 3-Wire US)
Go
f
x
Angle using Current in Each Outer (2-Phase 3-Wire US)
Go
f
x
Angle using Current in Neutral Wire (2-Phase 3-Wire US)
Go
f
x
Volume of Conductor Material using Resistance (2 Phase 3 Wire US)
Go
f
x
Volume of Conductor Material (2 Phase 3 Wire US)
Go
f
x
Maximum Voltage using Volume of Conductor Material (2-phase 3-wire US)
Go
f
x
Maximum Voltage using Line Losses (2-Phase 3-Wire US)
Go
f
x
RMS Voltage using Line Losses (2-Phase 3-Wire US)
Go
f
x
Current in Neutral Wire (2-Phase 3-Wire US)
Go
f
x
Current in Each Outer (2-Phase 3-Wire US)
Go
f
x
Maximum Voltage using Current in Each Outer (2-Phase 3-Wire US)
Go
f
x
RMS Voltage using Current in Each Outer (2-Phase 3-Wire US)
Go
f
x
RMS Voltage using Current in Neutral Wire (2-Phase 3-Wire US)
Go
f
x
Maximum Voltage using Current in Neutral Wire (2-Phase 3-Wire US)
Go
f
x
Power Factor using Line Losses (2-Phase 3-Wire US)
Go
f
x
Power Factor using Current in Each Outer (2-Phase 3-Wire US)
Go
f
x
Power Factor using Current in Neutral Wire (2-Phase 3-Wire US)
Go
List of variables in 2 Φ 3 Wire System formulas
f
x
Line Losses
Go
f
x
Volume Of Conductor
Go
f
x
Maximum Voltage Underground AC
Go
f
x
Phase Difference
Go
f
x
Resistivity
Go
f
x
Length of Underground AC Wire
Go
f
x
Area of Underground AC Wire
Go
f
x
Current Underground AC
Go
FAQ
What is the Power Transmitted?
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work. Power Transmitted is usually measured using the Watt for Power. Note that the value of Power Transmitted is always negative.
Can the Power Transmitted be negative?
Yes, the Power Transmitted, measured in Power can be negative.
What unit is used to measure Power Transmitted?
Power Transmitted is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Transmitted can be measured.
Let Others Know
✖
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!