FormulaDen.com
Physics
Chemistry
Math
Chemical Engineering
Civil
Electrical
Electronics
Electronics and Instrumentation
Materials Science
Mechanical
Production Engineering
Financial
Health
You are here
-
Home
»
Engineering
»
Electrical
»
Power System
Negative Sequence Voltage LG in L G Fault Formulas
Negative Sequence Voltage LG consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. And is denoted by V
2(lg)
. Negative Sequence Voltage LG is usually measured using the Volt for Electric Potential. Note that the value of Negative Sequence Voltage LG is always negative.
Formulas to find Negative Sequence Voltage LG in L G Fault
f
x
Negative Sequence Voltage using A-Phase Current (LGF)
Go
f
x
Negative Sequence Voltage for LGF
Go
f
x
Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LGF)
Go
L G Fault formulas that make use of Negative Sequence Voltage LG
f
x
Positive Sequence Current using Fault Impedance(LGF)
Go
f
x
Negative Sequence Current for L-G-F
Go
f
x
A-Phase Current using Sequence Voltages and Fault Impedance(LGF)
Go
f
x
Zero Sequence Voltage using A-Phase Current (LGF)
Go
f
x
A-Phase Voltage using Sequence Voltages(LGF)
Go
f
x
Zero Sequence Voltage using Positive Sequence Current
Go
f
x
Fault Impedance given Sequence Voltages(LGF)
Go
f
x
Negative Sequence Impedance for L-G-F
Go
List of variables in L G Fault formulas
f
x
Fault Impedance LG
Go
f
x
A-Phase Current LG
Go
f
x
Positive Sequence Voltage LG
Go
f
x
Zero Sequence Voltage LG
Go
f
x
Negative Sequence Impedance LG
Go
f
x
Negative Sequence Current LG
Go
f
x
A Phase EMF LG
Go
f
x
Zero Sequence Impedance LG
Go
f
x
Positive Sequence Impedance LG
Go
FAQ
What is the Negative Sequence Voltage LG?
Negative Sequence Voltage LG consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Negative Sequence Voltage LG is usually measured using the Volt for Electric Potential. Note that the value of Negative Sequence Voltage LG is always negative.
Can the Negative Sequence Voltage LG be negative?
Yes, the Negative Sequence Voltage LG, measured in Electric Potential can be negative.
What unit is used to measure Negative Sequence Voltage LG?
Negative Sequence Voltage LG is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Negative Sequence Voltage LG can be measured.
Let Others Know
✖
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!