Negative Sequence Impedance LG in L G Fault Formulas
Negative Sequence Impedance LG consists of balanced three-phase impedance phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. And is denoted by Z
2(lg)
. Negative Sequence Impedance LG is usually measured using the Ohm for Electric Resistance. Note that the value of Negative Sequence Impedance LG is always negative.
Formulas to find Negative Sequence Impedance LG in L G Fault
f
x
Negative Sequence Impedance for L-G-F
Go
f
x
Negative Sequence Impedance using A-Phase EMF (LGF)
Go
L G Fault formulas that make use of Negative Sequence Impedance LG
f
x
Negative Sequence Current for L-G-F
Go
f
x
Zero Sequence Current using A-Phase EMF (LGF)
Go
f
x
Positive Sequence Current using A-Phase EMF (LGF)
Go
f
x
Negative Sequence Current using A-Phase EMF (LGF)
Go
f
x
A-Phase Current using A-Phase EMF(LGF)
Go
f
x
A-Phase Current using Fault Voltage and Fault Impedance(LGF)
Go
f
x
A-Phase EMF using Zero Sequence Current (LGF)
Go
f
x
A-Phase EMF using Positive Sequence Current(LGF)
Go
f
x
A-Phase EMF using Negative Sequence Current (LGF)
Go
f
x
Positive Sequence Voltage using A-Phase EMF and Sequence Impedances(LGF)
Go
f
x
Negative Sequence Voltage for LGF
Go
f
x
Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LGF)
Go
f
x
Positive Sequence Impedance using A-Phase EMF (LGF)
Go
f
x
Zero Sequence Impedance using A-Phase EMF (LGF)
Go
f
x
Fault Impedance given A-Phase EMF and Sequence Impedances(LGF)
Go
f
x
Fault Impedance using Fault Voltage and A-Phase Current(LGF)
Go
List of variables in L G Fault formulas
f
x
Negative Sequence Voltage LG
Go
f
x
Negative Sequence Current LG
Go
f
x
EMF Induced in Primary Winding LG
Go
f
x
Fault Impedance LG
Go
f
x
Positive Sequence Impedance LG
Go
f
x
Zero Sequence Impedance LG
Go
FAQ
What is the Negative Sequence Impedance LG?
Negative Sequence Impedance LG consists of balanced three-phase impedance phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Negative Sequence Impedance LG is usually measured using the Ohm for Electric Resistance. Note that the value of Negative Sequence Impedance LG is always negative.
Can the Negative Sequence Impedance LG be negative?
Yes, the Negative Sequence Impedance LG, measured in Electric Resistance can be negative.
What unit is used to measure Negative Sequence Impedance LG?
Negative Sequence Impedance LG is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Negative Sequence Impedance LG can be measured.