Line Losses in 3 Φ 4 Wire System Formulas
Line Losses is defined as the total losses occurring in an Underground AC line when in use. And is denoted by P
loss
. Line Losses is usually measured using the Watt for Power. Note that the value of Line Losses is always negative.
Formulas to find Line Losses in 3 Φ 4 Wire System
f
x
Line Losses using Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Line Losses using Load Current (3 Phase 4 Wire US)
Go
f
x
Line Losses using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Line Losses (3 Phase 4 Wire US)
Go
3 Φ 4 Wire System formulas that make use of Line Losses
f
x
Power Transmitted using Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Power Transmitted using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Power Transmitted using Line Losses (3 Phase 4 Wire US)
Go
f
x
RMS Voltage using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Power Factor using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Power Factor using Line Losses (3 Phase 4 Wire US)
Go
f
x
RMS Voltage using Line Losses (3 Phase 4 Wire US)
Go
f
x
RMS Voltage using Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Maximum Voltage using Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Maximum Voltage using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Maximum Voltage using Line Losses (3 Phase 4 Wire US)
Go
f
x
Load Current using Line Losses (3 Phase 4 Wire US)
Go
f
x
Load Current using Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Angle using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Length using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Volume of Conductor Material using Load Current (3 Phase 4 Wire US)
Go
f
x
Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Angle using Line Losses (3 Phase 4 Wire US)
Go
f
x
Area using Line Losses (3 Phase 4 Wire US)
Go
f
x
Length using Line Losses (3 Phase 4 Wire US)
Go
f
x
Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Volume of Conductor Material when Resistance is Given(3 Phase 4 Wire US)
Go
f
x
Resistivity using Volume of Conductor Material (3 Phase 4 Wire US)
Go
f
x
Resistivity using Area of X-Section (3 Phase 4 Wire US)
Go
f
x
Resistivity using Load Current (3 Phase 4 Wire US)
Go
f
x
Resistivity using Line Losses (3 Phase 4 Wire US)
Go
f
x
Resistance using Line Losses (3 Phase 4 Wire US)
Go
f
x
Resistance using Volume of Conductor Material (3 Phase 4 Wire US)
Go
List of variables in 3 Φ 4 Wire System formulas
f
x
Power Transmitted
Go
f
x
Resistivity
Go
f
x
Length of Underground AC Wire
Go
f
x
Maximum Voltage Underground AC
Go
f
x
Phase Difference
Go
f
x
Volume Of Conductor
Go
f
x
Current Underground AC
Go
f
x
Area of Underground AC Wire
Go
FAQ
What is the Line Losses?
Line Losses is defined as the total losses occurring in an Underground AC line when in use. Line Losses is usually measured using the Watt for Power. Note that the value of Line Losses is always negative.
Can the Line Losses be negative?
Yes, the Line Losses, measured in Power can be negative.
What unit is used to measure Line Losses?
Line Losses is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Line Losses can be measured.