Line Losses in 1 Φ 2 Wire Mid Point Earthed System Formulas
Line Losses is defined as the total losses occurring in an Underground AC line when in use. And is denoted by P
loss
. Line Losses is usually measured using the Watt for Power. Note that the value of Line Losses is always negative.
Formulas to find Line Losses in 1 Φ 2 Wire Mid Point Earthed System
f
x
Line Losses using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
1 Φ 2 Wire Mid Point Earthed System formulas that make use of Line Losses
f
x
Power Transmitted using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Power Transmitted using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Power Factor using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Power Factor using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Maximum Voltage using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Maximum Voltage using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
RMS Voltage using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
RMS Voltage using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Length using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Area using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Angle using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Volume of Conductor Material (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Volume of Conductor Material using Resistance (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Resistance using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Resistivity using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Go
f
x
Resistivity using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Go
List of variables in 1 Φ 2 Wire Mid Point Earthed System formulas
f
x
Resistivity
Go
f
x
Length of Underground AC Wire
Go
f
x
Power Transmitted
Go
f
x
Area of Underground AC Wire
Go
f
x
Maximum Voltage Underground AC
Go
f
x
Phase Difference
Go
FAQ
What is the Line Losses?
Line Losses is defined as the total losses occurring in an Underground AC line when in use. Line Losses is usually measured using the Watt for Power. Note that the value of Line Losses is always negative.
Can the Line Losses be negative?
Yes, the Line Losses, measured in Power can be negative.
What unit is used to measure Line Losses?
Line Losses is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Line Losses can be measured.