Distance from Compression to Tensile Reinforcement is defined as the distance from extreme compression surface to the centroid of tensile reinforcement, in (mm). And is denoted by d. Distance from Compression to Tensile Reinforcement is usually measured using the Millimeter for Length. Note that the value of Distance from Compression to Tensile Reinforcement is always positive.
Ultimate Strength Design of Concrete Columns formulas that make use of Distance from Compression to Tensile Reinforcement
f
x
Ultimate Strength for Symmetrical Reinforcement
Go
f
x
Ultimate Strength for No Compression Reinforcement
Go
f
x
Ultimate Strength for Symmetrical Reinforcement in Single Layers
Go
FAQ
What is the Distance from Compression to Tensile Reinforcement?
Distance from Compression to Tensile Reinforcement is defined as the distance from extreme compression surface to the centroid of tensile reinforcement, in (mm). Distance from Compression to Tensile Reinforcement is usually measured using the Millimeter for Length. Note that the value of Distance from Compression to Tensile Reinforcement is always positive.
Can the Distance from Compression to Tensile Reinforcement be negative?
No, the Distance from Compression to Tensile Reinforcement, measured in Length cannot be negative.
What unit is used to measure Distance from Compression to Tensile Reinforcement?
Distance from Compression to Tensile Reinforcement is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Distance from Compression to Tensile Reinforcement can be measured.