FormulaDen.com
Physics
Chemistry
Math
Chemical Engineering
Civil
Electrical
Electronics
Electronics and Instrumentation
Materials Science
Mechanical
Production Engineering
Financial
Health
You are here
-
Home
»
Engineering
»
Civil
»
Environmental Engineering
Critical Depth in Constant Velocity Horizontal Flow Grit Channels Formulas
Critical Depth occurs when the flow in a channel has a minimum specific energy. Specific energy refers to the sum of the depth of flow and the velocity head. And is denoted by d
c
. Critical Depth is usually measured using the Meter for Length. Note that the value of Critical Depth is always positive.
Formulas to find Critical Depth in Constant Velocity Horizontal Flow Grit Channels
f
x
Critical Depth in Control Section
Go
f
x
Critical Depth given Discharge through Control Section
Go
f
x
Critical Depth at Different Discharges
Go
f
x
Critical Depth given Depth of Parabolic Channel
Go
f
x
Critical Depth given Maximum Discharge
Go
Constant Velocity Horizontal Flow Grit Channels formulas that make use of Critical Depth
f
x
Total Energy at Critical Point
Go
f
x
Total Critical Energy
Go
f
x
Critical Velocity given Total Energy at Critical Point
Go
f
x
Critical Velocity given Critical Depth in Control Section
Go
f
x
Critical Velocity given Discharge through Control Section
Go
f
x
Critical Velocity given Maximum Discharge
Go
f
x
Discharge through Control Section
Go
f
x
Discharge given Critical Depth
Go
f
x
Maximum Discharge given Width of Throat
Go
f
x
Depth of Parabolic Channel given Critical Depth
Go
f
x
Width of Throat given Discharge through Control Section
Go
f
x
Width of Throat given Critical Depth
Go
f
x
Width of Throat given Maximum Discharge
Go
List of variables in Constant Velocity Horizontal Flow Grit Channels formulas
f
x
Critical Velocity
Go
f
x
Acceleration due to Gravity
Go
f
x
Environmental Discharge
Go
f
x
Width of Throat
Go
f
x
Depth
Go
f
x
Peak Discharge
Go
FAQ
What is the Critical Depth?
Critical Depth occurs when the flow in a channel has a minimum specific energy. Specific energy refers to the sum of the depth of flow and the velocity head. Critical Depth is usually measured using the Meter for Length. Note that the value of Critical Depth is always positive.
Can the Critical Depth be negative?
No, the Critical Depth, measured in Length cannot be negative.
What unit is used to measure Critical Depth?
Critical Depth is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Critical Depth can be measured.
Let Others Know
✖
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!