Characteristic Impedance in Travelling Waves Formulas
The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition. And is denoted by Z
0
. Characteristic Impedance is usually measured using the Ohm for Electric Resistance. Note that the value of Characteristic Impedance is always negative.
Formulas to find Characteristic Impedance in Travelling Waves
f
x
Characteristic Impedance for Incident Waves
Go
f
x
Characteristic Impedance for Reflected Waves
Go
f
x
Characteristic Impedance using Reflected Voltage
Go
f
x
Characteristic Impedance using Reflected Current
Go
f
x
Characteristic Impedance using Transmitted Coefficient of Current
Go
f
x
Characteristic Impedance using Transmitted Coefficients
Go
Travelling Waves formulas that make use of Characteristic Impedance
f
x
Load Impedance using Reflected Voltage
Go
f
x
Incident Voltage using Reflected Current
Go
f
x
Reflected Current using Load Impedance
Go
f
x
Transmitted Voltage using Incident Current
Go
f
x
Incident Voltage using Transmitted Voltage
Go
f
x
Incident Current using Transmitted Current
Go
f
x
Load Impedance using Transmitted Current
Go
f
x
Transmitted Current using Incident Current
Go
f
x
Load Impedance using Transmitted Coefficient of Voltage
Go
f
x
Load Impedance using Transmitted Coefficient of Current
Go
f
x
Transmitted Voltage (Load SC)
Go
f
x
Transmitted Current (Load OC)
Go
f
x
Transmitted Coefficient of Current using Transmitted Coefficient of Voltage
Go
f
x
Transmitted Coefficient of Voltage using Transmitted Coefficient of Current
Go
f
x
Load Impedance using Transmitted Coefficients
Go
List of variables in Travelling Waves formulas
f
x
Incident Voltage
Go
f
x
Incident Current
Go
f
x
Reflected Voltage
Go
f
x
Reflected Current
Go
f
x
Load Impedance
Go
f
x
Transmission Coefficient of Current
Go
f
x
Transmission Coefficient of Voltage
Go
FAQ
What is the Characteristic Impedance?
The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition. Characteristic Impedance is usually measured using the Ohm for Electric Resistance. Note that the value of Characteristic Impedance is always negative.
Can the Characteristic Impedance be negative?
Yes, the Characteristic Impedance, measured in Electric Resistance can be negative.
What unit is used to measure Characteristic Impedance?
Characteristic Impedance is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Characteristic Impedance can be measured.
Let Others Know
✖
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!